Component Type Short Term Avg. Corrosion Rate (mm/yr) Long Term Avg. Corrosion Rate (mm/yr) Remaining Life (yrs)
VESSEL 0.051  0.026  8.634

NDE

Inspection Location Location Description Component Type Status Nominal Thickness (mm) Minimum Thickness (mm) Initial Reading (mm)
A-12  12 O’Clock Vessel Active 22.0000 16.9055  22.0000
A-3  3 O’Clock Vessel Active  22.0000 16.9055  22.0000
A-6  6 O’Clock Vessel Active  22.0000 16.9055  22.0000
A-9  9 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-12  12 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-3  3 O’Clock Vessel Active 22.0000 16.9055  22.0000
B-6  6 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-9  9 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-9  9 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-9  9 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-9  9 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-9  9 O’Clock Vessel Active  22.0000 16.9055  22.0000
B-9  9 O’Clock Vessel Active  22.0000 16.9055  22.0000
Initial Date Previous Rdg (mm) Previous Date Current Reading (mm) Current Date ST CR (mm/yr) LT CR (mm/yr) Remain Life (yrs)
1/1/1986 22.0000 1/1/1986 23.0000 07/11/2006 -0.04790 -0.04790  
1/1/1986 22.0000 1/1/1986 25.0000 07/11/2006 -0.14380 -0.14380  
1/1/1986 22.0000 1/1/1986 22.3000 07/11/2006 -0.01440 -0.01440  
1/1/1986 22.0000 1/1/1986 23.7000 07/11/2006 -0.08150 -0.08150  
1/1/1986 22.0000 1/1/1986 23.5000 07/11/2006 -0.07190 -0.07190  
1/1/1986 22.0000 1/1/1986 23.5000 07/11/2006 -0.07190 -0.07190  
1/1/1986 22.0000 1/1/1986 24.2000 07/11/2006 -0.10540 -0.10540  
1/1/1986 22.0000 1/1/1986 23.7000 07/11/2006 -0.08150 -0.08150  
1/1/1986 22.0000 1/1/1986 23.2000 07/11/2006 -0.05750 -0.05750  
1/1/1986 22.0000 1/1/1986 22.7000 07/11/2006 -0.03360 -0.03360  
1/1/1986 22.0000 1/1/1986 23.7000 07/11/2006 -0.08150 -0.08150  
1/1/1986 22.0000 1/1/1986          
1/1/1986 22.0000 1/1/1986 122.7000 07/11/2006 -0.03360 -0.03360  

Criticality

  Probability Category Inspection Priority Category
Internal Corrosion 4 15
External Corrosion 4 15
Environmental Cracking N/A N/A
Other Damage Mechanism N/A N/A

Corrosion Monitoring

PipeLine ID 250
Type Of PipeLine Crude
INLET WLP-C
Sampling Date 06-Apr-18
Sampling Time 09:45 AM
Pressure (psi) 78
Temp (°C) 36.6
Water Cut (%) 0
pH NA
CO2 (%) 6
H2S (ppm) 2
SRB (Cell/mL) NA
Remarks 100% crude

2017 JUL

CHEMSAIN
Sampling Point V-100 DRAIN (OUTLET)
Sampling Date 22-Jul-17
Sampling Time 08:30 AM
Received Date 27-Jul-17
Received Time 08:00AM
Rpt Ref No CK/CL305/15003-7/17
Rpt Date 09-Aug-17
Sampled by Mark/Donny
Type of Sample Formation Water
On-Site Test
Properties Unit Method
Temperature (Water) °C Temperature Gun 33.5
pH @ 25°C (water) pH Meter 8.2
Carbon Dioxide (gas) % Detector Tube 5
Hydrogen Sulphide (gas) mg/L Detector Tube 5
Dissolved Carbon Dioxide (water) mg/L Chemetrics
Lab Test
Properties Unit Method
Free Carbon Dioxide mg/L APHA 4500-CO2C
Density kg/m³ ASTM D 1429 1007
Conductivity µmhos/cm APHA 2510 B
Total Dissolved Solids mg/L APHA 2540 D 20,800
Total Suspended Solids mg/L Chemetrics 26
Chloride mg/L APHA 4500 CI- B 7,520
Salinity ppt APHA 210 C 20
Carbonate mg/L APHA 2320 B Absent
Bicarbonate mg/L APHA 2320 B 3,170
Total Alkalinity mg/L APHA 2320 B
p-alkalinity mg/L APHA 2320 B
Hydroxyl Ion mg/L APHA 2320 B
Total Hardness mg/L APHA 2340 B
Calcium Hardness mg/L APHA 3500-Ca B
Iron mg/L APHA 3030 F & 3120 B <0.03
Calcium mg/L APHA 3030 F & 3120 B 28.1
Magnesium mg/L APHA 3030 F & 3120 B 45.8
Sodium mg/L APHA 3030 F & 3120 B 6640
Potassium mg/L APHA 3030 F & 3120 B 134.0
Barium mg/L APHA 3030 F & 3120 B 3.86
Strontium mg/L APHA 3030 F & 3120 B 2.17
Bromide mg/L APHA 4110 B 25.5
Sulphate mg/L APHA 4500-SO4 2- E 18
Turbidity NTU APHA 2130 B
Sulphide mg/L APHA 4500-S2- D <0.1
Mercury mg/L APHA 3112 B
Total Fatty Acid (as acetic acid) mg/L In house Method 0543 by IC 280
Formic Acid mg/L In house Method 0543 by IC <1
Acetic Acid mg/L In house Method 0543 by IC 237
Propanoic Acid mg/L In house Method 0543 by IC 42.8
Butyric Acid mg/L In house Method 0543 by IC <1
Pentanoic Acid mg/L In house Method 0543 by IC <1
Hexanoic Acid mg/L In house Method 0543 by IC <1

2017 APR

CHEMSAIN
Sampling Point V-100 DRAIN (OUTLET)
Sampling Date 26-APR-17
Sampling Time 09:30 AM
Received Date 03-MAY-17
Received Time 08:00AM
Rpt Ref No CK/CL305/14348-7/17
Rpt Date 15-May-17
Sampled by Mark/Donny
Type of Sample Formation Water
On-Site Test
Properties Unit Method
Temperature (Water) °C Temperature Gun 30.5
pH @ 25°C (water) pH Meter 7.5
Carbon Dioxide (gas) % Detector Tube 2
Hydrogen Sulphide (gas) mg/L Detector Tube 1
Dissolved Carbon Dioxide (water) mg/L Chemetrics 70
Lab Test
Properties Unit Method
Free Carbon Dioxide mg/L APHA 4500-CO2C
Density kg/m³ ASTM D 1429 1008
Conductivity µmhos/cm APHA 2510 B
Total Dissolved Solids mg/L APHA 2540 D 14,100
Total Suspended Solids mg/L Chemetrics 32
Chloride mg/L APHA 4500 CI- B 6,500
Salinity ppt APHA 210 C 14
Carbonate mg/L APHA 2320 B Absent
Bicarbonate mg/L APHA 2320 B 4,000
Total Alkalinity mg/L APHA 2320 B
p-alkalinity mg/L APHA 2320 B
Hydroxyl Ion mg/L APHA 2320 B
Total Hardness mg/L APHA 2340 B
Calcium Hardness mg/L APHA 3500-Ca B
Iron mg/L APHA 3030 F & 3120 B 1.90
Calcium mg/L APHA 3030 F & 3120 B 52.9
Magnesium mg/L APHA 3030 F & 3120 B 39.0
Sodium mg/L APHA 3030 F & 3120 B 5280
Potassium mg/L APHA 3030 F & 3120 B 98.8
Barium mg/L APHA 3030 F & 3120 B 0.47
Strontium mg/L APHA 3030 F & 3120 B 2.86
Bromide mg/L APHA 4110 B 25.8
Sulphate mg/L APHA 4500-SO4 2- E 25.2
Turbidity NTU APHA 2130 B
Sulphide mg/L APHA 4500-S2- D <0.1
Mercury mg/L APHA 3112 B
Total Fatty Acid (as acetic acid) mg/L In house Method 0543 by IC 935
Formic Acid mg/L In house Method 0543 by IC <1
Acetic Acid mg/L In house Method 0543 by IC 872
Propanoic Acid mg/L In house Method 0543 by IC 77
Butyric Acid mg/L In house Method 0543 by IC <1
Pentanoic Acid mg/L In house Method 0543 by IC <1
Hexanoic Acid mg/L In house Method 0543 by IC <1

CHEMSAIN
Sampling Point V-100 DRAIN (OUTLET)
Sampling Date 16-Nov-16
Sampling Time 1:30 AM
Received Date 21-Nov-16
Received Time 08:00AM
Rpt Ref No CK/CL305/13090-3/16
Rpt Date 28-Nov-16
Sampled by Syahril/Martinus
Type of Sample Formation Water
On-Site Test
Properties Unit Method
Temperature (Water) °C Temperature Gun 29.5
pH @ 25°C (water) pH Meter 7.7
Carbon Dioxide (gas) % Detector Tube 2
Hydrogen Sulphide (gas) mg/L Detector Tube 1
Dissolved Carbon Dioxide (water) mg/L Chemetrics 70
Lab Test
Properties Unit Method
Free Carbon Dioxide mg/L APHA 4500-CO2C
Density kg/m³ ASTM D 1429 1009
Conductivity µmhos/cm APHA 2510 B
Total Dissolved Solids mg/L APHA 2540 D 14,000
Total Suspended Solids mg/L Chemetrics 26
Chloride mg/L APHA 4500 CI- B 6,080
Salinity ppt APHA 210 C 11
Carbonate mg/L APHA 2320 B Absent
Bicarbonate mg/L APHA 2320 B 3,560
Total Alkalinity mg/L APHA 2320 B
p-alkalinity mg/L APHA 2320 B
Hydroxyl Ion mg/L APHA 2320 B
Total Hardness mg/L APHA 2340 B
Calcium Hardness mg/L APHA 3500-Ca B
Iron mg/L APHA 3030 F & 3120 B 0.09
Calcium mg/L APHA 3030 F & 3120 B 24.3
Magnesium mg/L APHA 3030 F & 3120 B 10.2
Sodium mg/L APHA 3030 F & 3120 B 4820
Potassium mg/L APHA 3030 F & 3120 B 43.2
Barium mg/L APHA 3030 F & 3120 B 3.33
Strontium mg/L APHA 3030 F & 3120 B 3.22
Bromide mg/L APHA 4110 B 15.1
Sulphate mg/L APHA 4500-SO4 2- E 29.7
Turbidity NTU APHA 2130 B
Sulphide mg/L APHA 4500-S2- D <0.1
Mercury mg/L APHA 3112 B
Total Fatty Acid (as acetic acid) mg/L In house Method 0543 by IC 1360
Formic Acid mg/L In house Method 0543 by IC <1
Acetic Acid mg/L In house Method 0543 by IC 1260
Propanoic Acid mg/L In house Method 0543 by IC 120
Butyric Acid mg/L In house Method 0543 by IC <1
Pentanoic Acid mg/L In house Method 0543 by IC <1
Hexanoic Acid mg/L In house Method 0543 by IC <1